Home

PLC 110 · PLC Control I

Session 7 · Hour 1 · Draw the walk first

Instructor cue 짐작은 선도가 아니다.

90 minNow Open · 5 min left · next Demo

I show · you follow · check

The lecturer shows once. You copy the same move next.

A step is a bit

Residual air bites. Dump the air. Then the scan.

Name what a stepper bit stands for, and the first safety on air

0/6

  • Machine. Sequence. Sensors. I/O list. Wires. Then rungs.

  • Stepper: one move, one bit. Easy to read.

  • Cascade: groups. Fewer rungs. Harder to see.

  • Limit ON is the done. Then SET next, RST now.

  • A+ and A− cannot share a valve moment.

  • Dump air. Kill electric. Then look.

CheckWrite B+, A+, A−, B−. Map START and S1–S4 to X, solenoids to Y. Step bits M. F3 the walk. Init, cycle, mid-stop, e-stop home. A cylinder that will not step is sensor, step bit, valve, then jam — in that order. Residual air bites.